Silicon Labs /SiM3_NRND /SIM3L166_C /ACCTR_0 /LCMODE

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as LCMODE

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLED)ATRKEN 0 (DISABLED)ACDEN 0 (ZERO)LCD0HYS 0 (ZERO)LCD1HYS 0 (ZONEA)C0ZONE 0 (ZONEA)C1ZONE 0 (DISABLED)P0ZONE 0 (DISABLED)P1ZONE 0 (DISABLED)PMD0 (DISABLED)B0ZONECEN 0 (DISABLED)B0ZONEBEN 0 (DISABLED)B0ZONEAEN 0 (DISABLED)B0ZONEPEN 0 (PULSE_LOW)B0POL 0 (DISABLED)B1ZONECEN 0 (DISABLED)B1ZONEBEN 0 (DISABLED)B1ZONEAEN 0 (DISABLED)B1ZONEPEN 0 (PULSE_LOW)B1POL 0 (MODE0)BMD0 (MODE0)LCMD

P0ZONE=DISABLED, B1POL=PULSE_LOW, B0ZONEBEN=DISABLED, P1ZONE=DISABLED, B0ZONEAEN=DISABLED, B1ZONEAEN=DISABLED, B0POL=PULSE_LOW, C0ZONE=ZONEA, LCD0HYS=ZERO, B0ZONEPEN=DISABLED, C1ZONE=ZONEA, LCD1HYS=ZERO, ACDEN=DISABLED, ATRKEN=DISABLED, PMD=DISABLED, LCMD=MODE0, B1ZONECEN=DISABLED, B0ZONECEN=DISABLED, B1ZONEPEN=DISABLED, BMD=MODE0, B1ZONEBEN=DISABLED

Description

LC Mode

Fields

ATRKEN

Automatic Tracking Enable.

0 (DISABLED): Disable automatic tracking.

1 (ENABLED): Enable automatic tracking. A new MAX value of any size will increase both the MAX and MIN by 1, and a new MIN value of any size will decrease both the MAX and MIN by 1.

ACDEN

Automatic Center Discriminator Enable.

0 (DISABLED): Disable automatic center discriminator mode. Firmware must set the CD0 and CD1 fields.

1 (ENABLED): Enable automatic center discriminator mode. Hardware will keep the CD0 and CD1 fields centered between MAX and MIN.

LCD0HYS

LC Discriminator 0 Digital Hysterisis.

0 (ZERO): A high-to-low transition occurs if LCCOUNT0 is less than CD0.

1 (MINUS1): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 1.

2 (MINUS2): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 2.

3 (MINUS3): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 3.

LCD1HYS

LC Discriminator 1 Digital Hysterisis.

0 (ZERO): A high-to-low transition occurs if LCCOUNT1 is less than CD1.

1 (MINUS1): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 1.

2 (MINUS2): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 2.

3 (MINUS3): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 3.

C0ZONE

Counter 0 Active Zone Select.

0 (ZONEA): Select zone A as the active zone for counter 0 (LCIN0 input).

1 (ZONEB): Select zone B as the active zone for counter 0 (LCIN0 input).

2 (ZONEC): Select zone C as the active zone for counter 0 (LCIN0 input).

3 (ZONED): Select zone D as the active zone for counter 0 (LCIN0 input).

C1ZONE

Counter 1 Active Zone Select.

0 (ZONEA): Select zone A as the active zone for counter 1 (LCIN1 input).

1 (ZONEB): Select zone B as the active zone for counter 1 (LCIN1 input).

2 (ZONEC): Select zone C as the active zone for counter 1 (LCIN1 input).

3 (ZONED): Select zone D as the active zone for counter 1 (LCIN1 input).

P0ZONE

Pulse 0 Active Zone Select.

0 (DISABLED): Disable the pulse 0 output (LCPUL0).

1 (C_ONLY): Select zone C only as the active zone for the pulse 0 output (LCPUL0).

2 (A_ONLY): Select zone A only as the active zone for the pulse 0 output (LCPUL0).

3 (A_AND_C): Select zones A and C as the active zones for the pulse 0 output (LCPUL0).

P1ZONE

Pulse 1 Active Zone Select.

0 (DISABLED): Disable the pulse 1 output (LCPUL1).

1 (C_ONLY): Select zone C only as the active zone for the pulse 1 output (LCPUL1).

2 (A_ONLY): Select zone A only as the active zone for the pulse 1 output (LCPUL1).

3 (A_AND_C): Select zones A and C as the active zones for the pulse 1 output (LCPUL1).

PMD

LC Pulse Mode.

0 (DISABLED): Disable pulse mode.

1 (TOGGLE): Toggle at the start of zone A or zone C.

2 (PULSE_LOW): Set the pulse mode to idle high, pulse low.

3 (PULSE_HIGH): Set the pulse mode to idle low, pulse high.

B0ZONECEN

Bias 0 Zone C Enable.

0 (DISABLED): Disable bias 0 during zone C.

1 (ENABLED): Enable bias 0 during zone C.

B0ZONEBEN

Bias 0 Zone B Enable.

0 (DISABLED): Disable bias 0 during zone B.

1 (ENABLED): Enable bias 0 during zone B.

B0ZONEAEN

Bias 0 Zone A Enable.

0 (DISABLED): Disable bias 0 during zone A.

1 (ENABLED): Enable bias 0 during zone A.

B0ZONEPEN

Bias 0 Zone P Enable.

0 (DISABLED): Disable bias 0 during zone P.

1 (ENABLED): Enable bias 0 during zone P.

B0POL

Bias 0 Polarity.

0 (PULSE_LOW): Set bias 0 to idle high, pulse low.

1 (PULSE_HIGH): Set bias 0 to idle low, pulse high.

B1ZONECEN

Bias 1 Zone C Enable.

0 (DISABLED): Disable bias 1 during zone C.

1 (ENABLED): Enable bias 1 during zone C.

B1ZONEBEN

Bias 1 Zone B Enable.

0 (DISABLED): Disable bias 1 during zone B.

1 (ENABLED): Enable bias 1 during zone B.

B1ZONEAEN

Bias 1 Zone A Enable.

0 (DISABLED): Disable bias 1 during zone A.

1 (ENABLED): Enable bias 1 during zone A.

B1ZONEPEN

Bias 1 Zone P Enable.

0 (DISABLED): Disable bias 1 during zone P.

1 (ENABLED): Enable bias 1 during zone P.

B1POL

Bias 1 Polarity.

0 (PULSE_LOW): Set bias 1 to idle high, pulse low.

1 (PULSE_HIGH): Set bias 1 to idle low, pulse high.

BMD

Bias Mode.

0 (MODE0): Disable the bias signals.

1 (MODE1): Use the bias signals externally only (LCBIAS0 and LCBIAS1 outputs).

2 (MODE2): Use the bias signals internally only.

3 (MODE3): Use the bias signals externally (LCBIAS0 and LCBIAS1 outputs) and internally.

LCMD

LC Mode.

0 (MODE0): The LC pulse asserts throughout zone A or zone C with a single-ended comparator using the counter and discriminator.

1 (MODE1): The LC pulse asserts throughout zone A or zone C with differential comparators using the counter and discriminator.

2 (MODE2): The LC pulse asserts throughout zone A or zone C with a single-ended comparator sampling and holding at the end of the LC pulse.

3 (MODE3): The LC pulse asserts throughout zone A or zone C with differential comparators sampling and holding at the end of the LC pulse.

4 (MODE4): The LC pulse starts at the beginning of zone A or C and stops with the timer with a single-ended comparator using the counter and discriminator.

5 (MODE5): The LC pulse starts at the beginning of zone A or C and stops with the timer with differential comparators using the counter and discriminator.

6 (MODE6): The LC pulse starts at the beginning of zone A or C and stops with the timer with a single-ended comparator sampling and holding at the end of the LC pulse.

7 (MODE7): The LC pulse starts at the beginning of zone A or C and stops with the timer with differential comparators sampling and holding at the end of the LC pulse.

8 (MODE8): The LC pulse starts at beginning of zone A or C and stops with the rising edge of the external stop input (STOPx) with a single-ended comparator using the counter and discriminator.

9 (MODE9): The LC pulse starts at beginning of zone A or C and stops with the falling edge of the external stop input (STOPx) with single-ended comparators using the counter and discriminator.

10 (MODE10): The LC pulse starts at beginning of zone A or C and stops with the rising edge of the external stop input (STOPx) with a single-ended comparator sampling and holding at the end of the LC pulse.

11 (MODE11): The LC pulse starts at beginning of zone A or C and stops with the falling edge of the external stop input (STOPx) with single-ended comparators sampling and holding at the end of the LC pulse.

12 (MODE12): Do not generate a pulse with a single-ended comparator using the timer and discrimintor.

13 (MODE13): Do not generate a pulse with differential comparators using the timer and discrimintor.

14 (MODE14): Do not generate a pulse with a single-ended comparator sampling and holding at the end of the zone.

15 (MODE15): Do not genreate a pulse with differential comparators sampling and holding at the end of the zone.

Links

()